Face View of
Female
Description Cat. No.
Receiver Termination
Plug
898D-81CU-DM
Termination plug 8-pin M12 quick disconnect
Required for connection to top connector of cascadable receiver if cascade light curtain is used as a standalone system or as the last segment pair in
a cascaded system.
Note: A termination plug is not necessary for the cascadable transmitter.
Cordsets Approximate Dimensions [mm (in.)]
Dimensions are not intended to be used for installation purposes.
Straight Female M12 Quick Disconnect
ArmorBlock Guard I/O
Top View Color No. of Pins Signal
Receiver
Brown 1 +24V
White 2 OSSD 2
Blue 3 0V
Black 4 OSSD 1
Grey 5 NC
InterconnectingPatchcords—ArmorBlockI/OConnection
Cat. No. Description
889D-F5ACDM-0M3 Five-pin M12 patchcord, 0.3 m (12 in.)
889D-F5ACDM-1 Five-pin M12 patchcord, 1 m (39.37 in.)
889D-F5ACDM-2 Five-pin M12 patchcord, 2 m (78.74 in.)
889D-F5ACDM-5 Five-pin M12 patchcord, 5 m (196.85 in.)
889D-F5ACDM-10 Five-pin M12 patchcord, 10 m (393.7 in.)
Note: The GuardShield pairs with ArmorBlock Guard I/O Connectivity have a 5-pin M12 quick-disconnect connector on the receiver wired to allow connection to the ArmorBlock 5-pin connector.
The transmitter in that GuardShield pair is a standard GuardShield transmitter with integrated laser alignment system offered with a 4-pin M12 quick-disconnect connector. It is possible to
connect either a standard 4-pin M12 cordset or the 5-pin M12 quick-disconnect connector cordset or patchcord to this transmitter.
Termination Connector for Cascadable GuardShield Receiver (if it's a standalone pair) with ArmorBlock Guard I/O Connectivity
Face View of Female Description Cat. No.
5-pin M12
Termination Adaptor
898D-418U-DM
Note: The cascadable GuardShield with ArmorBlock Guard I/O connectivity can be used as a standalone pair if the top connector on the receiver has a termination adaptor connected. The
cascadable transmitter does not require a termination adaptor.
Optional Accessories